R22 Refrigerant Rules of Thumb

  • R-22 Low-Side pressure = 30 psi at 90°F ambient temperature.
  • R-22 Low-Side Typical Operating Pressure-Range = 58 – 85 psig (varying by indoor wet bulb temperature and outdoor ambient temperature, where higher heat loads increase the vapor line pressure)

Similarly, What should the suction line pressure be?

Your desired suction pressure is 33-48 degrees or 58-80 psi depending on the indoor temperature. (Note: The hot or warm air from a hot house traveling across the evaporator coil will warm the refrigerant faster than normal causing a higher suction pressure.

Additionally, What should R-22 pressures be at 70 degrees? If the outdoor temperature is 70°F, a refrigerant bottle outside would have a pressure of roughly 201 PSIG. If the outdoor temperature is 110°F, a refrigerant bottle outside would have a pressure of roughly 366 PSIG.

How can you tell if R-22 is low?


7 Signs Your AC Unit is Low on Refrigerant

  1. It takes a long time for your home to cool off. …
  2. Vents are not blowing cool air. …
  3. The temperature you set is never reached. …
  4. Your electric bill is higher than normal. …
  5. Ice on refrigerant lines. …
  6. Water leaking around heater. …
  7. Hissing or bubbling noise.

What should my gauges read on 410A?

During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG.

Why is my suction pressure low?

Many reasons can cause low refrigerant suction pressure, i.e.: low indoor temperature, dirty filters, restricted ducts, undersized ducts, closed dampers, frosted coils, restricted refrigerant line, restricted piston, incorrect piston, restricted strainer, bad indoor blower motor ect.

What are normal operating pressures for 410A?

A normally operating R-410A system with the same condensation temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig.

What should my superheat be for R22?

For example, 68 psi suction pressure on a R-22 system converts to 40F. Let’s say the suction line temperature is 50F. Subtracting the two numbers gives us 10F of superheat. Superheat for most systems should be approximately 10F measured at the evaporator; 20F to 25F near the compressor.

Do you flip R22 upside down?

R22 is a single gas so it is the usual practice to fill as a gas. The newer R410A is a mixture of gases, and must be filled as a liquid (upside down).

How do I know if my refrigerant is low?


Five Signs your AC is Low on Freon

  1. It takes much longer than it should to cool off your home. …
  2. Your utility bills are higher than usual. …
  3. The air coming out of your vents isn’t cold. …
  4. Ice has started to build up on your refrigerant line. …
  5. You hear loud or unusual noises coming from your unit.

What pressure should 410A be at 80 degrees?

R-410A Pressure Temperature Chart

PSIG(Pounds per Square Inch Gauge) R-410A (HFC) °Fahrenheit

78

20

80

21

85

24

90

26

How do I know if my 410A is overcharged?


6 Symptoms That Your Air Conditioner Is Overcharged With…

  1. Inflating Energy Bills. …
  2. Increasing Heat Discharge. …
  3. Developing Frost Layers. …
  4. Squealing from the Compressor. …
  5. Shutting Down Entirely. …
  6. Measuring Uneven Pressure Levels.

What causes low suction pressure and high discharge pressure?

The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line.

What causes low suction and low head pressure?

This can be caused by low air flow (dirty filter, slipping belt, undersized or restricted ductwork, dust and dirt buildup on blower wheel) or a dirty or plugged evaporator coil. Checking superheat will indicate if the low suction is caused by insufficient heat getting to the evaporator.

What causes low pressure in refrigeration?

Low evaporator pressure: Low evaporator pressure is caused by the compressor being starved of refrigerant. The compressor is trying to draw refrigerant into its cylinders, but there isn’t enough refrigerant to satisfy it. The entire low side of the system will experience low pressure.

What is the recommended pressure for pressure testing of R410A refrigerant?

For R410A refrigerant, this means the test needs to be at almost 500 psig. The higher pressure means that relief devices and some components need to be removed and then reinstalled on the system after the test is complete.

How much superheat should I have?

When ambient air temp (Outside air temp) is 75-85 degrees the superheat should be 12-15 degrees, if the ambient temperature is 85 degrees or over the superheat should be 8-12 degrees.

What is the ideal superheat and subcooling?

Most heating and cooling systems should operate at a superheat of 10F at the evaporator and between 20F to 25F at the compressor. if your HVAC system has a thermostatic expansion valve (TXV), the subcooling should be between 10F and 18F.

Should you turn freon can upside down?

Registered. 35 is okay for the low side under a load (engine speed raised to about 2500 RPM. At idle, it should stabilize at about 30. Turn the can upside down to help it evacuate better.

Do you charge R22 as a vapor or liquid?

Blends like R410a or 404a must be added to a system as a liquid. Pure refrigerants like R22 can be added in liquid or vapor states. If adding liquid into the suction like, throttle it in slowly to avoid slugging the compressor or diluting and washing out the compressor oil.

What happens when refrigerant is low?

With less refrigerant, there is less heat absorption. The coil remains cold, and moisture begins to freeze across it. The more frost develops, the more the level of heat absorption drops, initiating a downward cycle the will end with a solid block of ice covering the indoor coil that fully blocks heat exchange.

What is the pressure of R 410A at 72 degrees Fahrenheit?

Example: What is the pressure of r410a at 72 degrees Fahrenheit? We can see that at 72°F, the R410A pressure is 208,4 psig.

What should suction line temp be 410A?

The suction temperature should be above 35°F and below 65°F entering the compressor and the discharge line temperature should be below 220°F and above 150°F (typically) on a properly functioning package unit.